Hawke Logo
My AccountMy Account
Quick product navigation //
OR

Group II Hazardous Area Cable Glands

American Series Glands NEC/IEC

Group 1 Mining Cable Glands

Industrial Cable Glands

Thread Conversions and Accessories

Plugs

Exe/Exd

Adaptor/Reducers 476

Exe/Exd

Thread converters inline

and right angled swivel adaptors
Exe/Exd

Breather Drain

Exe/Exd

Fixed Inline Adaptors

Exe/Exd

Unions

Exe/Exd

Insulated Adaptors

Exe/Exd

Earth Lead Adaptor 383

Exe

Accessories

View all

Connector Selection

Enclosures

PL511 Enclosure

PL511

Increased Safety Exe
Dual Certified ATEX - IECEx
PL513 Enclosure

PL513

Increased Safety Exe
Dual Certified ATEX - IECEx
PL520 Enclosure

PL520

Increased Safety Exe
Dual Certified ATEX - IECEx
PL612 Enclosure

PL612

Increased Safety Exe
Dual Certified ATEX - IECEx
PL615 Enclosure

PL615

Increased Safety Exe
Dual Certified ATEX - IECEx
PL620 Enclosure

PL620

Increased Safety Exe
Dual Certified ATEX - IECEx
PL626 Enclosure

PL626

Increased Safety Exe
Dual Certified ATEX - IECEx
PL630 Enclosure

PL630

Increased Safety Exe
Dual Certified ATEX - IECEx
PL642 Enclosure

PL642

Increased Safety Exe
Dual Certified ATEX - IECEx
PL644 Enclosure

PL644

Increased Safety Exe
Dual Certified ATEX - IECEx
PL712 Enclosure

PL712

Increased Safety Exe
Dual Certified ATEX - IECEx
PL722 Enclosure

PL722

Increased Safety Exe
Dual Certified ATEX - IECEx
EJB-Series Stainless Steel Enclosures

EJB Range

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 1 Enclosure

Size 1

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 2 Enclosure

Size 2

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 2L Enclosure

Size 2L

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 3 Enclosure

Size 3

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 4 Enclosure

Size 4

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 4L Enclosure

Size 4L

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 5 Enclosure

Size 5

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 6 Enclosure

Size 6

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 7 Enclosure

Size 7

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 8 Enclosure

Size 8

Increased Safety Exe
Dual Certified ATEX - IECEx
Size 9 Enclosure

Size 9

Increased Safety Exe
Dual Certified ATEX - IECEx
EA 231513 Enclosure

EA 231513

Increased Safety Exe
Dual Certified ATEX - IECEx
EA 262620 Enclosure

EA 262620

Increased Safety Exe
Dual Certified ATEX - IECEx
EA 303020 Enclosure

EA 303020

Increased Safety Exe
Dual Certified ATEX - IECEx
EA 352620 Enclosure

EA 352620

Increased Safety Exe
Dual Certified ATEX - IECEx
EA 403020 Enclosure

EA 403020

Increased Safety Exe
Dual Certified ATEX - IECEx
EA 463820 Enclosure

EA 463820

Increased Safety Exe
Dual Certified ATEX - IECEx
EA 484820 Enclosure

EA 484820

Increased Safety Exe
Dual Certified ATEX - IECEx
EA 553522 Enclosure

EA 553522

Increased Safety Exe
Dual Certified ATEX - IECEx
EA 624522 Enclosure

EA 624522

Increased Safety Exe
Dual Certified ATEX - IECEx
View full connector range

Powerex logo

Hazardous Area Connector

Tamb: -40°C to +60°C. ex logo II2 GD Exdb IIC Extb IIIC Db T85 IP66, 67 & DTS01 deluge protected.

PowerEx Connector

Overview

The Powerex logo range of connectors have been designed specifically for the extremely demanding requirements of higher power applications.

Inserts are available with 1 to 4 contacts with a conductor acceptance range of between 50mm2 and 630mm2 operating up to 780A and 750V as standard. Other voltages available on special request.

Powerex logo Features

    • 1 Running Coupler

      Allows the connector to be installed onto a pre-assembled cable gland.

    • 2 Keying Position

      The unique visual 5 position insert keying system along with the the integral machined keyway prevents contact damage and ensures safe use by eliminating the possibility of misconnection of adjacent circuits.

    • 3 Internal Earth

      Internal earth fitted as standard. Sized to suit cables earthing facility.

    • 4 Easy Fieldwireable

      Insert assembled outside connector shell to assist wiring and allow greater flexibility.

    • 5 Multilam Technology

      Tried and tested multiple high contact force, low resistance multilams used in all contacts.

    • 6 Acme Thread At Mating Interface

      Unique ACME thread offers a smooth and quick fully mating action.

Mouse over the features above for more information or

1 Running Coupler

Allows the connector to be installed onto a pre-assembled cable gland.

2 Keying Position

The unique visual 5 position insert keying system along with the the integral machined keyway prevents contact damage and ensures safe use by eliminating the possibility of misconnection of adjacent circuits.

3 Internal Earth

Internal earth fitted as standard. Sized to suit cables earthing facility.

4 Easy Fieldwireable

Insert assembled outside connector shell to assist wiring and allow greater flexibility.

5 Multilam Technology

Tried and tested multiple high contact force, low resistance multilams used in all contacts.

6 Acme Thread At Mating Interface

Unique ACME thread offers a smooth and quick fully mating action.

Assembly Instructions

AI 365
Inserts
Dimensions

Powerex logo Connector Dimensions

PowerEx Connector Dimensions

For connector plugs and connector receptacles, cable glands are required to terminate incoming cables. These can be selected from the cable gland section of our website. These cable glands include but are not restricted to 501/453/Universal and the ICG 653/Universal.

DIMENSIONS (MM)
Dimension Ex32P Ex40P Ex50P Ex63P Ex75P
A 228 228 228 228 238
B 168 168 168 168 178
ØC 60 66 76 89 101
ØD 73 79 89 102 114
E 251 251 251 251 261
ØF 67 73 82.5 95 108
ØP 48 55 65 78 90
R 60 60 60 60 60
S 75.5 75.5 75.5 75.5 76
ØT 61 68 77 90 102
U 68.5 68.5 68.5 68.5 68.5
Thread V (1.5mm Pitch) M32* M40* M50* M63* M75*
ØW 100 106 116 129 141
X 184 184 184 184 194
* Other entry threads available upon request.

Powerex logo Inserts

PowerEx Connector Inserts
INSERT SELECTION TABLE
Configuration
Shell Size 32 Shell Size 40 Shell Size 50 Shell Size 63 Shell Size 75
1 x 50mm² + Earth 1 x 185mm² + Earth 3 x 50mm² + Earth 3 x 95mm² + Earth 3 x 185mm² + Earth
1 x 70mm² + Earth 1 x 240mm² + Earth 3 x 70mm² + Earth 3 x 120mm² + Earth 3 x 240mm² + Earth
1 x 95mm² + Earth - 4 x 50mm² + Earth 3 x 150mm² + Earth 4 x 185mm² + Earth
1 x 120mm² + Earth - 4 x 70mm² + Earth 4 x 95mm² + Earth 4 x 240mm² + Earth
1 x 150mm² + Earth - 1 x 185mm² + Earth 4 x 120mm² + Earth 1 x 500mm² + Earth
- - 1 x 240mm² + Earth 4 x 150mm² + Earth 1 x 630mm² + Earth
- - - 1 x 300mm² + Earth -
- - - 1 x 400mm² + Earth -
All Hawke Powerex logo Connectors have a maximum working voltage of (750V AC).
Other voltages and contact configurations also available contact us for details.

Powerex logo Calculations

To select the shell size of the connector, it is essential that you calculate the dissipated wattage of the arrangement. This ensures that the arrangement does not exceed the maximum permitted temperature classification with regard to the upper ambient temperature for the area of installation. (please refer to table 1 below for the maximum allowable dissipated wattage per connector size).

TABLE 1
Connector Size Upper Ambient
Temperature of +40°C
Upper Ambient
Temperature of +50°C
Upper Ambient
Temperature of +60°C
Temperature Class Temperature Class Temperature Class
T6 T5 T6 T5 T6 T5
Ex32P 20.5W 27.5W 15.75W 26W 7.5W 15.75W
Ex40P 22.5W 30.5W 17.5W 28W 8.7W 17.5W
Ex50P 25.8W 35.3W 20W 32.25W 10W 20W
Ex63P 30.2W 41.5W 23.5W 37.7W 11.7W 23.5W
Ex75P 36.3W 49.5W 28.25W 45.25W 14W 28.25W
  Maximum allowable dissipated wattage
Other ambient temperature options can be extrapolated from
table 1 above, or contact Hawke International for more information.
TABLE 2
Contact Size Combined Cable And Contact Resistance (Ohms) Contact Current Rating
50mm² 514 190 amps
70mm² 387 240 amps
95mm² 283 290 amps
120mm² 239 340 amps
150mm² 202 385 amps
185mm² 170 440 amps
240mm² 144 520 amps
300mm² 82 590 amps
400mm² 67 670 amps
500mm² 54 720 amps
630mm² 45 780 amps

Dissipated Wattage Calculation

Equation definitions:

W = Dissipated wattage factor of the connector

N = The number of conductors to be terminated/number of contacts required. (Note: A contact comprises of a pin and socket).

I = The current requirement per contact. (Note: This must be equal to or less than the maximum current rating of the contact, as shown in table 2 above).

R = The combined cable and contact resistance (see table 2 above).

Values pertinent to these definitions must then be input into the relevant fields below to calculate the dissipated wattage (W) of your chosen arrangement:

1. W = N x I ² x R
N I R Dissipated Wattage
(Watts)
W

Note: The result must be lower than the maximum figure shown in table 1 above, for the appropriate temperature class and ambient temperature).

e.g. T6 40°C ambient application with 4 x 95mm² conductors running at 160 amps.
N = 4 contacts
I = 160 amps
R = 0.000283 ohms (95mm² soldered combined cable and contact resistance)

Therefore W = 4 x 25600 x 0.000283 = 28.9 watts.
Therefore an Ex63P Connector should be specified for this application as the shell size can accommodate the required 4 x 95mm² pin / socket inserts (see insert selection table) and the resultant dissipated wattage (28.9 watts) is below the maximum permitted 30.2 watts (see table 1 above).

This equation can also be transposed to facilitate the calculation of the maximum number of conductors permitted in your selected connector (calculator 2 below ) and the maximum allowable current within the upper ambient temperature of your location (calculator 3 below).

2. number of conductors formula
W R I Maximum Number Of
Conductors
N
3. maximum current formula
W N R Current
(Amps)
I
Note: The result must not exceed the maximum current rating of the contacts (see table 2 above)

Note: Unless otherwise requested, connectors will be marked as T5 with an upper ambient temperature of +40°C.

Order Codes

When ordering, select the relevant code from each block as shown in the example below:
Powerex logo/Exd-50-S-CR-A-4-50-S-FLFRC-A-1

Powerex logo Select Code Description Example Code
Protection Exd Flameproof Exd
Shell Size 32 32 50
40 40
50 50
63 63
75 75
Material B Brass
Note: (for single core cables, Brass must be used)
S
S Stainless Steel (as standard)
N Nickel Plated Brass
Connector Style CP Connector Plug CR
CR Connector Receptacle
BR Bulkhead Receptacle
Internal Earth Size
Note: Should be at least 50% of phase conductor size
A 50mm² A
B 70mm²
C 95mm²
D 120mm²
E 150mm²
F 185mm²
G 240mm²
Number Of Contacts   See insert selection  
Contact Type   Contact Type Maximum Conductor Acceptance Diameter (mm) 50
50 50mm² 9.5
70 70mm² 11.5
95 95mm² 13
120 120mm² 14.5
150 150mm² 16.5
185 185mm² 18.5
240 240mm² 20.5
300 300mm² 25
400 400mm² 29
500 500mm² 32
630 630mm² 38
X No Insert
Insert Type P Pin S
S Socket
Accessories
* Note: only the connector receptacle (CR) can be flange mounted.
FL Mounting Flange * FLFRC
FPC Flameproof Plug Cap
FRC Flameproof Receptacle Cap
PPC Environmental Plug Cap
PRC Environmental Receptacle Cap
Certification A ATEX/IECEx/EAC/INMETRO A
N ATEX/IECEx/EAC/INMETRO /NEC 505
Voltage reduced to 600V
Ambient Rating & Temperature Class
T5 +40°C will be supplied as standard if alternative not specified
1 T5 +40°C Standard 1
2 T5 +50°C
3 T5 +60°C
4 T6 +40°C
5 T6 +50°C
6 T6 +60°C

Find A Connector Modifier

Ordering Information

For ordering information and codes, please see order codes tab.

Download Data Sheet