S-Series Size 3 Enclosure - Cable Gland Entry Positions For Faces B & D
All dimensions in millimetres.
General Tolerance : +/- 0.25
| SIZE 3 CABLE GLAND ENTRY POSITIONS (Faces B & D) | ||
|---|---|---|
| Max. Entries |
Standard Positions Of Entries (Maximum Sizes Shown - Equivalent Parallel Threads Or Smaller Permissible) |
|
| 23 | M16 M20/O |
1P 6P 9P 13P 17P 21P 24P 29P 3U 8U 12U 15U 18U 22U 27U 1Z 6Z 9Z 13Z 17Z 21Z 24Z 29Z |
| 16 | M20/A | 1R 6R 9R 13R 17R 21R 24R 29R 1Y 6Y 9Y 13Y 17Y 21Y 24Y 29Y |
| 8 | M25 | 2S 11S 16S 23S 7X 14X 19X 28X |
| 5 | M32 | 4T 15T 26T 10W 20W |
| 4 | M40 | 3U 12U 18U 27U |
| 3 | M50 | 5U 15U 25U |
Entry Positions Based On Hawke Cable Glands
M16/M20/O - 24.0 Across Flats, 27.7 Across Corners.
M20/A - 30.0 Across Flats, 34.6 Across Corners.
M25 - 36.0 Across Flats, 41.6 Across Corners.
M32 - 46.0 Across Flats, 53.1 Across Corners.
M40 - 55.0 Across Flats, 63.5 Across Corners.
M50 - 65.0 Across Flats, 75.1 Across Corners.