PL Series Enclosures Maximum Physical Quantity Of Terminals


W Series And Direct Mounted Terminals

MAXIMUM PHYSICAL QUANTITY OF TERMINALS
Terminal Type Enclosure Type
PL612 PL615 PL620 PL626 PL630 PL712 PL722
1 Diagonal Rail 2 Vertical Rails
WDU 2.5N 12 + 1 Earth
(1 central or offset entry only)
N/A N/A 38 + 1 Earth N/A N/A 12 + 1 Earth
(1 central entry only)
N/A
WDU 2.5 10 + 1 Earth
(1 offset entry only)
14 + 1 Earth 24 + 1 Earth 38 + 1 Earth 50 + 1 Earth 76 + 2 Earths
(38 + 1 earth per rail)
10 + 1 Earth
(1 central entry only)
35 + 1 Earth
(No entries on faces B & D)
WDU 4 10 + 1 Earth
(1 offset entry only)
12 + 1 Earth 20 + 1 Earth 32 + 1 Earth 42 + 1 Earth 64 + 2 Earths
(32 + 1 earth per rail)
10 + 1 Earth
(1 central entry only)
29 + 1 Earth
(No entries on faces B & D)
WDU 6 7 + 1 Earth
(1 offset entry only)
9 + 1 Earth 15 + 1 Earth 24 + 1 Earth 30 + 1 Earth 48 + 2 Earths
(24 + 1 earth per rail)
7 + 1 Earth
(1 central entry only)
22 + 1 Earth
(No entries on faces B & D)
WDU 10 6 + 1 Earth
(1 offset entry only)
7 + 1 Earth 12 + 1 Earth 19 + 1 Earth 25 + 1 Earth 36 + 2 Earths
(18 + 1 earth per rail)
6 + 1 Earth
(1central entry only)
17 + 1 Earth
(No entries on faces B & D)
WDU 16 N/A 6 + 1 Earth
(1 offset entry only)
9 + 1 Earth 16 + 1 Earth 20 + 1 Earth 30 + 2 Earths
(15 + 1 earth per rail)
N/A N/A
WDU 35 N/A N/A 6 + 1 Earth 12 + 1 Earth 15 + 1 Earth 22 + 2 Earths
(11 + 1 earth per rail)
N/A N/A
WDU50N N/A N/A 5 + 1 Earth N/A 11 + 1 Earth N/A N/A N/A
WDU 70N N/A N/A 4 + 1 Earth N/A 11 + 1 Earth
(Conductor termination
difficult - Advise 9 + 1 Earth)
N/A N/A N/A
BK6 1 N/A N/A N/A N/A N/A 1 N/A
MK6/6 1 N/A N/A N/A N/A N/A 1 N/A
HTB/6 1 1 2 N/A N/A N/A 1 N/A

Notes:

Earths (PL612 and PL712) The rail earths may be replaced by a pillar earth, but a bracket shall be fitted at the end of the terminal stack in it's place.

Entries (PL612, PL615 ,PL626, PL712 and PL722) Where the quantity of entries has been restricted, this is due to limited space. If multiple entries are required, then the quantity of power terminals shall be reduced accordingly. PL712 - It may be possible for some maximum terminal assemblies to use two M20/O entry positions.

Rails (PL612, PL615, PL620 and PL712) 1 Diagonal rail.
PL 626 and PL722: 1 Horizontal rail.
PL630: 1 diagonal or 2 vertical rails.

Maximum physical quantity of terminals PL series enclosures datasheet adobe pdf logo