PL626 Enclosure
Technical Data
Increased Safety Exe.
II 2 GD Exe II, ExtD.
Baseefa Certificate No. Baseefa06ATEX0117X.
Baseefa Certificate No. Baseefa06ATEX0116U.
IECEx Certificate No. IECEx BAS 06.0028X.
IECEx Certificate No. IECEx BAS 06.0027U.
Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22.
Construction and test standards IEC 60079-0, IEC 60079-7, IEC 61241-0 and IEC 61241-1.
EN 60079-0, EN 60079-7, EN61241-0 and EN 61241-1.
IP66 and IP67 ingress protection to IEC 60529 and EN 60529.
DTS01 deluge protection witnessed by Baseefa 2001.
Operating temperature range -60°C to +75°C.
Temperature class and ambient T6 40°C.
Optional T5 with ambients up to 65°C.
Alternative certification options available:
AExe II/Exe II.
GOST R-Exe IIU.

PL626 Enclosure

| MAXIMUM QUANTITY OF ENTRIES | |||||
|---|---|---|---|---|---|
| Thread Size | M16 | M20/O | M20/A | M25 | M32 |
| Face A / C | 9 | 9 | 7 | 4 | 3 |
| Face B / D | 3 | 3 | 3 | 2 | 1 |
| TERMINAL CAPACITY DATA | ||||||||
|---|---|---|---|---|---|---|---|---|
| Terminal Type | Conductor Size (mm²) | Max. Volts |
Max. No. Of Terminals | High Power Applications | ||||
| Min. | Max. | Terminal Quantity |
Amps | Terminal Quantity |
Amps | |||
| WDU 2.5 | 0.5 | 2.5 | 550 | 38 | 11 | 15 | 17 | |
| WDU 4 | 0.5 | 4 | 690 | 32 | 15 | 14 | 22 | |
| WDU 6 | 0.5 | 6 | 550 | 24 | 20 | 11 | 29 | |
| WDU 10 | 1.5 | 10 | 550 | 19 | 28 | 9 | 40 | |
| WDU 16* | 1.5 | 16 | 690 | 16 | 39 | 8 | 53 | |
| WDU 35* | 2.5 | 35 | 690 | 12 | 62 | 6 | 87 | |
| * Rail mounted directly onto the box. | ||||||||
Notes:
- A combination of different sized entries is possible, please contact Hawke for more information.
- The table above gives an indication of potential terminal arrangements. Please contact Hawke for information on other arrangements or empty Enclosures.
- A combination of different sized terminals is possible, please contact Hawke for more information.
- Other terminal types are available.
An earth terminal equal to that of the largest power terminal will be fitted.
The terminals listed are restricted to a minimum operating temperature of -50°C.