PL615 Enclosure

Technical Data

Increased Safety Exe. ex logo II 2 GD Exe II, ExtD.
Baseefa Certificate No. Baseefa06ATEX0117X.
Baseefa Certificate No. Baseefa06ATEX0116U.
IECEx Certificate No. IECEx BAS 06.0028X.
IECEx Certificate No. IECEx BAS 06.0027U.
Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22.
Construction and test standards IEC 60079-0, IEC 60079-7, IEC 61241-0 and IEC 61241-1.
EN 60079-0, EN 60079-7, EN61241-0 and EN 61241-1.
IP66 and IP67 ingress protection to IEC 60529 and EN 60529.
DTS01 deluge protection witnessed by EECS.
Operating temperature range -60°C to +75°C.
Temperature class and ambient T6 40°C.
Optional T5 with ambients up to 65°C.

Alternative certification options available:
flag of canada canadian standards association logo Exe II.
flag of U.S.A. underwriters laboratories logo AExe II/Exe II.
flag of russia gost logo R-Exe IIU.
flag of kazakhstan Approved for use in Kazakhstan.

PL615 Enclosure

PL615 enclosure dimensions

MAXIMUM QUANTITY OF ENTRIES PER FACE
Thread Size M16/M20 M25 M32
Quantity 2 2 1
TERMINAL CAPACITY DATA
Terminal Type Conductor Size (mm²) Max.
Volts
Max. Physical
Terminal Content
Reduced Terminal Content
At Max. Terminal Amps
Min. Max. Terminal
Quantity
Amps Terminal
Quantity
Amps
WDU 2.5 0.5 2.5 550 14 16 13 17
WDU 4 0.5 4 690 12 21 11 22
WDU 6 0.5 6 550 9 29 9 29
WDU 10 1.5 10 550 7 40 7 40
WDU 16 1.5 16 690 6 53 6 53
HTB6 0.5 Max. Per
Pillar
550 1 Conductor
Size mm2
Max. Amps
Per Pillar
N/A N/A
2 x 10mm²
3 x 6mm²
4 x 4mm²
4 x 0.5mm² Min.
0.5
0.75
1
1.5
2.5
4
6
10
1
1
8
10
15
21
26
37

An earth terminal equal to that of the largest power terminal will be fitted.
The terminals listed are restricted to a minimum operating temperature of -50°C.