Membership

Forgot your password?

For access to product selection applications, technical FAQ, downloads and more please register with us

755 Cable Gland/Connector

Application

755 cable gland Outdoor or indoor use.
For use with armoured jacketed cable, as permitted by the NEC.

Features

Provides a barrier seal between the individual insulated conductors within the cable and prevents entry of the products of an explosion into the cable.
Assembly of the cable gland/connector compresses and distributes the compound evenly to create a barrier seal at the point of entry into the enclosure.
Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured red to indicate hazardous locations product.
Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket.

Materials & Finishes

The 755 cable gland/connector is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminum.
Brass NPT entries are nickel plated as standard.

Technical Data

UL Listing No: E84940.
Suitable for use in:
Class 1, Division 2, Gas Groups A, B , C and D.
Class 1, Zone 2, Gas Groups IIA, IIB and IIC.
AExd IIC and AExe II Class 1, Zone 2.
Flameproof Exd, Increased Safety Exe ex logo II 2 GD and Restricted Breathing ExnR ex logo II 3G.
Sira Certificate No. Sira 06ATEX1295X
IECEx Certificate NO. IECEx Sir 06.0082X
Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.
Construction and Test Standards: UL 2225, IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0 and IEC/EN 61241-1.
Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.
Deluge protection to DTS01.
Operating Temperature Range: -50°C to +60°C (UL) and -60°C to + 80°C (ATEX / IECEx).
Note: 755 cable glands are supplied dual ATEX/UL marked as standard.
Alternative certification options available:
DNV logo Marine Approval
ABS logo Marine Approval Certificate No. 06-LD142850D-PDA.
flag of russia GOST logo GOST R-Exe IIU.
RINA logoRINA Certificate No. ELE030710CS


755 Cable Gland/Connector

755 cable gland
CABLE GLAND/CONNECTOR SELECTION TABLE
Size
Ref.
Entry
Thread Size
Cable Acceptance Details ‘G’
Compressed
Length
Hexagon
Dimensions
Inner Sheath/Cores ‘B’
Outer
Jacket
‘C’
NPT Metric
*
‘D’
Max.
Over
Cores
‘E’
Max.
Inner
Sheath
Max.
No.
Of
Cores
Across
Flats
Across
Corners
Standard Option Min. Max. Steel Wire
Armour ††
Braid Tape
Os ½" - M20 ‡ 0.35" 0.46" 6 0.22" 0.47" 0.036" / 0.049" 0.008" / 0.013" 0.008" / 0.031" 2.61" 0.94" 1.09"
O ½" - M20 ‡ 0.35" 0.46" 6 0.37" 0.63" 0.036" / 0.049" 0.008" / 0.013" 0.008" / 0.031" 2.61" 0.94" 1.09"
A ½" ¾" M20 0.43" 0.49" 10 0.49" 0.81" 0.036" / 0.049" 0.008" / 0.013" 0.008" / 0.031" 2.65" 1.18" 1.36"
B ¾" 1" M25 0.64" 0.72" 21 0.66" 1.02" 0.049" / 0.062" 0.008" / 0.013" 0.008" / 0.039" 2.75" 1.42" 1.64"
C 1" 1¼" M32 0.86" 0.97" 42 0.87" 1.30" 0.062" / 0.078" 0.008" / 0.013" 0.008" / 0.055" 2.93" 1.81" 2.09"
C2 1¼" 1½" M40 1.04" 1.16" 60 1.10" 1.61" 0.062" / 0.078" 0.008" / 0.013" 0.008" / 0.070" 3.15" 2.17" 2.50"
D 2" 1½" M50 1.46" 1.64" 80 1.42" 2.07" 0.078" / 0.098" 0.008" / 0.013" 0.008" / 0.070" 3.14" 2.56" 2.96"
E 2½" 2" M63 1.88" 2.11" 100 1.81" 2.57" 0.098" 0.008" / 0.013" 0.008" / 0.070" 3.42" 3.15" 3.64"
F 3" 2½" M75 2.32" 2.61"/2.57" † 120 2.24" 3.07" 0.098" 0.008" / 0.013" 0.008" / 0.070" 3.61" 3.74" 4.31"
All dimensions in inches (except*).
All metric entry threads are 1.5mm pitch as standard.
† Smaller value is applicable when selecting the standard NPT entry thread.
‡Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner jacket diameter is 0.43".
†† UL listing only applies to Steel Wire Armour.

Ordering Information

Cable Gland Type/Size/Thread
e.g. 755/C/1" NPT

Two part sealing compound and assembly instructions are supplied with the cable gland.