501/423 Cable Gland
Application
Outdoor or Indoor use.
For use with non-armoured elastomer and plastic insulated cables.
May be used on cables incorporating inner and outer cable sheaths.
Features
Provides a cable retention seal onto the cables outer sheath at two independent sealing points.
When used in increased safety applications, this cable gland may be used with braided cable where the braid and the cables outer sheath pass into the enclosure. The braid must be suitably terminated inside the enclosure.
Materials & Finishes
The 501/423 Cable Gland is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium..
Brass NPT entries are nickel plated as standard.
Technical Data
Flameproof Exd and Increased Safety Exe.
II 2 GD
Baseefa Certificate No. Baseefa06ATEX0056X.
IECEx Certificate No. IECEx BAS 06.0013X.
Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22.
Suitable for use in Gas Groups IIA, IIB and IIC.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1. IEC 60079-0, IEC 60079-1 and IEC 60079-7.
IP66, IP67 and IP68 (30 metres for 7 days) ingress protection to IEC 60529, EN 60529 and NEMA 4X.
DTS01 deluge protection certified by ITS.
Additional deluge protection seal also available.
Operating temperature range -60°C to +100° as standard.
Alternative certification options available:
Option available, Exd IIC, Exe II. Certificate No. 1015065 (LR 78713-7).
Option available, BR-Exd IIC/Exe II. Certificate No. CEPEL-EX-060/2001X.
AUS-Exd IIC/Exe II. Certificate No. AUS 03,4008X.
Marine Approval. Certificate No. 06-LD142850A-PDA.
Marine Approval. Certificate No.E-8003.
501/423 Cable Gland

| CABLE GLAND SELECTION TABLE | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Size Ref. |
Entry Thread Size |
Thread Length ‘H’ |
Cable Acceptance Details | ‘G’ Compressed Length |
Hexagon Dimensions |
||||||
| Outer Sheath ‘B’ | |||||||||||
| Metric | NPT * |
Standard Seal |
Alternative (S) Seal |
Across Flats |
Across Corners |
||||||
| Standard | Option | Min. | Max. | Min. | Max. | ||||||
| Os | M20 ‡ | ½" | - | 15.0 | 3.0 | 8.0 | - | - | 52.3 | 24.0 | 27.7 |
| O | M20 ‡ | ½" | - | 15.0 | 7.5 | 11.9 | - | - | 52.3 | 24.0 | 27.7 |
| A | M20 | ¾" | ½" | 15.0 | 11.0 | 14.3 | 8.5 | 13.4 | 51.5 | 30.0 | 34.6 |
| B | M25 | 1" | ¾" | 15.0 | 13.0 | 20.2 | 9.5 | 15.4 | 54.7 | 36.0 | 41.6 |
| C | M32 | 1¼" | 1" | 15.0 | 19.0 | 26.5 | 15.5 | 21.2 | 55.9 | 46.0 | 53.1 |
| C2 | M40 | 1½" | 1¼" | 15.0 | 25.0 | 32.5 | 22.0 | 28.0 | 58.1 | 55.0 | 63.5 |
| D | M50 | 2" | 1½" | 15.0 | 31.5 | 44.4/42.3 † | 27.5 | 34.8 | 74.3 | 65.0 | 75.1 |
| E | M63 | 2½" | 2" | 15.0 | 42.5 | 56.3/54.3 † | 39.0 | 46.5 | 73.2 | 80.0 | 92.4 |
| F | M75 | 3" | 2½" | 15.0 | 54.5 | 68.2/65.3 † | 48.5 | 58.3 | 75.0 | 95.0 | 109.6 |
| G | M80 | 3½" | - | 20.0 | 67.0 | 73.0 | - | - | 68.0 | 106.4 | 123.0 |
| H | M90 | 3½" | - | 20.0 | 67.0 | 77.6 | - | - | 68.0 | 115.0 | 132.8 |
| J | M100 | 4" | - | 20.0 | 75.0 | 91.6 | - | - | 68.0 | 127.0 | 146.7 |
| † Smaller value is applicable when selecting the option NPT entry thread. ‡ Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable outer sheath diameter is 10.9 mm. Os - F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering. All dimensions in millimetres (except * ). |
|||||||||||
Cable Gland Ordering Examples
Type/Size/Thread
e.g. 501/423/C/M32
501/423/C/1¼" NPT
Cable Gland with Alternative Seal (S)
e.g. 501/423/C/M32/S
501/423/C/1¼" NPT/S