Membership

Forgot your password?

For access to product selection applications, technical FAQ, downloads and more please register with us

114 Cable Gland

Application

114 cable glandOutdoor or Indoor use.
For use with non-armoured elastomer and plastic insulated cables installed in conduit.

Features

Provides a cable retention seal onto the cables outer sheath.
Provides female running coupler for cable gland or conduit entry.

Materials & Finishes

The 114 Cable Gland is manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium.
Brass NPT entries are nickel plated as standard.

Technical Data

Construction and test standards EN 50262.
IP66, IP67 and IP68 (30 metres for 7 days) ingress protection to IEC 60529 and EN 60529.
Operating temperature range -60°C to +100°C as standard.

114 cable gland
CABLE GLAND SELECTION TABLE
Size
Ref.
Male Entry
Thread Size
Female Entry
Thread Size
Cable Acceptance Details ‘G’
Compressed
Length
Hexagon
Dimensions
‘B’ Outer Sheath
Metric NPT
*
Metric NPT
#
Standard
Seal
Alternative
(S) Seal
Across
Flats
Across
Corners
Standard Option Min. Max. Min. Max.
A M20 ¾" ½" M20 - 11.0 14.3 8.5 13.4 63.9 30.0 34.6
B M25 1" ¾" M25 - 13.0 20.2 9.5 15.4 52.8 36.0 41.6
C M32 1¼" 1" M32 - 19.0 26.5 15.5 21.2 69.5 46.0 53.1
C2 M40 1½" 1¼" M40 - 25.0 32.5 22.0 28.0 72.3 55.0 63.5
D M50 2" 1½" M50 - 31.5 44.4/42.3 † 27.5 34.8 92.8 65.0 75.1
E M63 2½" 2" M63 - 42.5 56.3/54.3 † 39.0 46.5 93.2 80.0 92.4
F M75 3" 2½" M75 - 54.5 68.2/65.3 † 48.5 58.3 94.9 95.0 109.6
† Smaller value is applicable when selecting the option NPT entry thread.
All metric entry threads are 1.5mm pitch medium fit. All dimensions in millimetres (except * ).
# NPT female thread sizes equivalent to those shown in the table for the male thread size are available.
Hexagon dimensions as shown may alter.

Cable Gland Ordering Examples

Type/Size/Male Thread/Female Thread
e.g. 114/C/M32/M32
114/C/1¼" NPT/M32

Cable Gland with Alternative Seal (S)

e.g. 114/C/M32/M32/S
114/C/1¼" NPT/M32/S